Undergraduate experiment on Brownian motion using video microscopy

Authors

  • Renante R. Violanda Department of Physics, University of San Carlos

Abstract

This paper presents measurement of Boltzmann's constant by observing Brownian motion of polystyrene beads suspended in water. The measured value of the Boltzmann's constant is k = (1.49 ± 0.14) x 10-23 J/K which has percent error of 7.65% as compared to the accepted value (k =1.38 x 10-23 J/K). We also present method of doing video microscopy designed for an undergraduate laboratory.

Downloads

Issue

Article ID

SPP-2004-PA-22

Section

Poster Session PA

Published

2004-10-25

How to Cite

[1]
RR Violanda, Undergraduate experiment on Brownian motion using video microscopy, Proceedings of the Samahang Pisika ng Pilipinas 22, SPP-2004-PA-22 (2004). URL: https://proceedings.spp-online.org/article/view/SPP-2004-PA-22.