Developing a numerical ray-tracing algorithm to determine corneal wave aberrations from corneal elevation maps

Authors

  • Victor Arni Sicam ⋅ NL Department of Clinical Physics and Informatics, Vrije Universiteit Medical Center, The Netherlands
  • Gerrit L. van der Heijde ⋅ NL Department of Clinical Physics and Informatics, Vrije Universiteit Medical Center, The Netherlands
  • Adonis Flores ⋅ PH Department of Physics, University of San Carlos, Philippines

Abstract

This paper reports how we developed a ray-tracing algorithm written in MATLAB to determine corneal wave aberrations from corneal elevation maps. The algorithm is tested and the numerical errors were found to be practically small, making the algorithm potentially useful for data measured from human eyes.

Downloads

Issue

Article ID

SPP-2002-2B-03

Section

Biological and Medical Physics

Published

2002-10-23

How to Cite

[1]
VA Sicam, GL van der Heijde, and A Flores, Developing a numerical ray-tracing algorithm to determine corneal wave aberrations from corneal elevation maps, Proceedings of the Samahang Pisika ng Pilipinas 20, SPP-2002-2B-03 (2002). URL: https://proceedings.spp-online.org/article/view/SPP-2002-2B-03.